Air temp
Air Temp brings precision, probe-based temperature data to your most critical chilled and heated assets — the exact readings general sensors can't give you.
Key specs
±0.5°C
probe measurement accuracy
~3 years
typical battery life
10–30%
site-wide savings with the full ecosystem
Beyond general ambient readings — dedicated probe data protects product, cuts waste, and simplifies compliance.
Reduces energy waste
Identifies over-cooling or over-heating so compressor and heater runtime can be adjusted based on accurate data.
Protects stock
Early alarms for temperature deviations catch problems before high-value or perishable goods spoil.
Supports compliance
Automated logging and alarms help meet HACCP, ISO 22000, and BRC temperature requirements without manual checks.
Operational visibility
Door-open events and temperature trends become visible in the analytics platform, enabling targeted fixes.
Quantity is driven by how many critical temperature points need dedicated monitoring — general ambient sensing is already covered by Air Sense.
Single cold room / walk-in freezer
1–2 units
Commercial kitchen / QSR (hot + cold)
2–4 units
Supermarket / multi-cold-room retail
1–2 per major cold room
Multi-site or larger food service
3–6+ units
Pharmaceutical / regulated storage
1+ per critical zone
Air Temp operates on the same LoRa wireless network generated by the Air Connect module attached to your central Eniscope Hybrid hub — no WiFi required. It uses an internal temperature sensor plus support for external probes (standard 3m length, optional up to 5m) to measure air temperature or product/core temperature, such as simulated food temperature inside storage or holding equipment. The device itself is rated for placement in environments from –4°F to 140°F (–20°C to +60°C), while the external probe can measure a much wider range of –22°F to 248°F (–30°C to +120°C) with ±0.5°C accuracy. Two independent digital inputs monitor states like door open/closed or pulse signals from meters. All data transmits to the Eniscope Hybrid and onward to the Eniscope Analytics cloud platform for monitoring, historical logging, threshold alarms, and reporting. The device is battery-powered (two AA-format lithium thionyl chloride cells) for long service life with minimal maintenance, and is surface-mounted with a rugged housing suited to harsh commercial conditions.
Air Temp is most valuable anywhere temperature is critical for product safety, compliance, or energy efficiency: chilled environments like walk-in freezers, cold rooms, refrigerated storage, and display cases; heated environments like warming cabinets and hot holding stations; commercial kitchens supporting HACCP and food safety monitoring; retail and supermarket cold chain across multiple cold rooms and vertical displays; pharmaceutical and GDP logistics requiring continuous temperature recording for regulated ranges; and industrial process areas like drying or fermentation where probe-based core readings matter. It's frequently paired with Air Sense for broader environmental context and control devices like Air Ambient or Air Digital/Air Switch for automated response.
Air Temp is a sensing device that feeds data into the rest of the Eniscope Air suite: Eniscope Analytics for real-time dashboards and alarms, Air Ambient for temperature-band HVAC control, Air Digital and Air Switch for logic-based or scheduled asset control that responds to temperature conditions, Air Sense for complementary multi-parameter environmental context, and CUES (where available) for refrigeration control that responds to actual food temperature rather than air temperature. Together, these form a closed-loop monitoring and control system built around the Eniscope Hybrid hub, which can support 100+ Air devices on a single network.
No, they complement each other. Air Sense covers general ambient temperature, humidity, occupancy, and light. Air Temp is for dedicated, high-accuracy probe-based readings on specific critical assets.
Up to approximately 3 years at a 5-minute reporting interval, longer at lower reporting rates. Battery status is visible in the cloud platform with low-voltage alerts.
Yes. Two independent volt-free digital inputs can monitor states like door open/closed, or pulse signals from meters.
No. It communicates over LoRa wireless via the Air Connect module attached to your Eniscope Hybrid hub, completely separate from your building's WiFi network.
The device itself can be placed in environments from –4°F to 140°F (–20°C to +60°C). The external probe measures a wider range of –22°F to 248°F (–30°C to +120°C), with ±0.5°C accuracy.
It depends on how many critical temperature points need dedicated monitoring rather than general ambient sensing. See the deployment guidance table above for typical starting points by facility type, and we'll help you finalize exact quantities during a site assessment.
See how much you could save
Free 90-second report. Zero upfront cost.
Many commercial facilities unknowingly waste energy they’re already paying for. We use real-time monitoring and smart controls to identify and recapture that waste. We guarantee savings opportunities worth at least 1.5 times your monthly solution cost.
124 E Cranston Ave
Fowler, CO USA
Copyright © 2026 N2 LLC. All rights reserved.